Codis 35 VAV

Variable air volume damper applications

KOER-VAV
D E S C R I P T I O N

Codis 35 VAV was designed to control Variable Air Volume dampers. Its hardware platform is the same as Codis 35 FC with the addition of a CO2 sensor. Like the FC, it enables higher energy efficiency thanks to a powerful weekly scheduler, “Occupied” operating mode and a digital input for presence sensor connection or passive electromechanical switch (open window) connection.

F E A T U R E S
touchscreen-p

LCD with touchscreen

Touchscreen and intuitive graphical user interface enable quick and easy adjustment of operating functions and device settings.

ECM-p

Electronically Comutated Motor control

Support for EC motor control through direct connection to 10 V outputs.

temperature-hum-co2-2p

Temperature, humidity and CO2 measurement

Built-in sensors guarantee a cost effective solution by eliminating the need for additional installation of multiple external sensing devices.

timer-p

Scheduler and timers

Fully configurable week scheduler with 8 timers per day.

bacnet-p

Comunication

Support for BACNet MSTP communication protocol over RS485 enables easier system integration.

security-p

Password protection

Device operation can be forbidden for unauthorized personnel by enabling the password protection.

inout-p

Inputs & Outputs

Multiple analog inputs and outputs expand possibilities by enabling the connection of external sensors and devices.

fastinstalation-p

Quick and easy installation

Simple, error free, two step installation process.

A P P L I C A T I O N S

Codis 35 VAV

C35-VAV… can be used in ventilation applicatons for:
> Heating
> Cooling
> Dehumidification

And VAV applications:
> Single duct
> Single duct with electric heater
> Single duct and radiator
> Single duct with heating and/or cooling coil
> Single duct with serial fan
> Single duct with parallel fan
> Single duct with serial fan and heating or cooling coil
> Single duct with parallel fan and heating or cooling coil

Typical Application

KOER-shema_VAV

OFFICES

Staying late and alone at work without heating or cooling can only increase the level of stress for employees. With Codis and Compact BMS timer settings can be overridden and that one office can be kept heated or cooled. Good air quality and the right temperature help employees to stay productive and focused for longer periods of time.

RESTAURANTS

For the guests, the aroma of freshly prepared food is enjoyable and it can be a good marketing tool for the restaurant. But if the restaurant is not properly ventilated, the enjoyable aroma will become an unpleasant smell after just a few days. Codis 35 and the volatile organic compound (VOC) sensor ensure that the right balance of fresh air and a good atmosphere are part of the business image.

HOTELS

Home away from home is something that all guests are looking for in hotels. To achieve that feeling, guests should be able to adjust heating, cooling or ventilation settings in a simple and intuitive way. The clean and modern design of Codis and intuitive controls of Compact BMS are a perfect combination for HVAC management in rooms and for control of zones in hotels.

RESIDENTIAL

No matter which season it is, a home should always be kept within perfect temperature limits for family and friends to enjoy it. With Codis and Compact BMS home temperatures can be easily adjusted for different zones and different occasions. Also, better control of all home zones achieves significant savings for household costs.

S P E C I F I C A T I O N S
Technical specifications
specifications-FC-crtez
Power supply

Nominal voltage:
> Range ………. AC 24 V ± 15 %, DC 17… 39 V
> Consumption ………. 1.5 W typical

Analog inputs

Voltage:
> Range ………. 0 …10 V DC (1 mA max)
> Resolution ………. 10 mV
> Accuracy ………. ±0.9% (Full scale)

Resistance:
> Range ………. 803 … 1480 ohm -50 … +125 °C (PT1000)
> Resolution ………. 0.385 ohm 0.1 °C (PT1000)
> Accuracy ………. ±1.54 ohm ±0.4 °C (PT1000)

Binary input

Voltage free
Selectable (NO/NC)

Analog outputs

Voltage:
> Range ………. 0 … 10 V (1mA)
> Resolution ………. 10 mV
> Accuracy ………. ±0.9% (Full scale)

Temperature sensor

Temperature:
> Range ……….  0 … +50 °C
> Resolution ……….  0.0625 °C
> Accuracy ………. ±0.5 °C (typical) ±1 °C (maximum)

Humidity sensor (optional)

Humidity:
> Range ……….  0 – 100 % rH from 0 °C to 50 °C
> Accuracy ……….  2% at 25 °C

CO2 sensor (optional)

Carbon-dioxide:
> Range ……….  0 – 10000 ppm
> Accuracy ……….  ±50 ppm, ±3% measured value

Display

Graphic TFT LCD:
> Size ……….  3.5 inch
> Resolution ……….  320 x 240 pixel
> Color depth ……….  16 bit
> Touchscreen ……….  Single touch / Resistive

Real time clock

Battery ON time
> Range ……….  up to 2 days

RS485 (optional)

Bitrate ……….  76.8 kbps (up to 2000m)
Galvanic isolation ……….  > 480 V
Jumper selectable termination ………. 120 ohm

Weight and Dimensions

Width  ………. 100 mm
Height  ………. 79 m
Depth  ………. 25 mm
Weight ………. 140 g

Operating temperature

Range ………. 0 °C to +50 °C

Storage temperature

Range  ……….  -30 °C to +70 °C

Standards

CE conformity:
> EMC directive  ……….  2004/180/EC
> Low voltage directive  ……….  2006/95/EC

Degree of protection

Physical IP30
Electrical Class III